Filter Results By:

Products

Applications

Manufacturers

Power Line

overhead or buried cable carrying electric power.


Showing results: 751 - 765 of 782 items found.

  • 15 Amp 120 VAC Filter and Surge Arrestor

    AS-AC15 - Array Solutions

    - 15 amp 120VAC quad outlet for high power devices- Resettable circuit breaker protection, easy to use and reset- I EA standard input plug and #14 GA AC line cord for USA - standard interface- MOV surge arrestors included - for even more protection- High level of common mode and differential mode filtering digital noise and RF filtering eliminates- digital artifacts and RF interference - See chart- Front Panel Neon Blue AC ON indicator - just plain cool to look at, not too bright!- Double shielded box inside - for optimum filtering operation- Size 6W X 4H X 4 3/4 D in inches approx 3 lbs

  • Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module

    MODEL TMO-2A - Transducer Techniques, Inc

    The TMO-2A Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The unit provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Zero to full scale output is specified at 4-20 mA. The TMO-2A provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.

  • Complete Network Monitoring

    TiSCADA - Techimp HQ S.r.L

    After years of advanced Research, laboratory and on-field tests, Techimp has developed powerful and effective tools which can help asset managers to take critical decisions and manage power plants in a cost saving ways. Ti-SCADA implements a Real Time condition control of your asset, through a powerful Human Machine Interface (HMI) fully configurable, web based, displaying graphs, charts, trends, KPI, historical data, alarms and customizable reports. Ti-SCADA is a fundamental component of the new generation of Techimp on line condition monitoring systems. Ti-SCADA is designed as a Service Oriented Architecture (SOA) based on interoperability standard for industrial automation - OPC-UA - allowing high performance asset management solutions, tailored on customer needs, to be implemented.

  • Vibration Unit Tester

    BK2020B - BaKo Co., Ltd

    We developed the BK2020B as an upgrade to our BK2020 to test the electrical specifications (RPM, current, drop pulse, start up voltage) of your cylindrical or coin type vibration units. You can also test vibration level, noise, isolation resistance, and the DC resistance. The DUT power supply and all measurement components are self contained, so external devices aren't needed and the tester uses DSP, making it capable of fast, highly accurate and reliable measurements. The BK2020B is very versatile. It can be set up as a stand alone machine, or used with a PC and software for access to more information, and to save the data for analysis. Either version is great on the product line but you may also use it for QA, QC and development.

  • GAOTek Three-Channel Leakage Current Tester

    GT00YB00ZV - GAO Tek Inc.

    The GAOTek Three-Channel Leakage Current Tester provides online measurement, monitoring, and recording of three channel AC leakage currents simultaneously by adopting the latest CT and magnetic shielding technology. This instrument provides highly accurate and reliable measurements. Additionally, it can locate insulation faults and repair electrical lines. It is composed of a special alloy and consists of a test monitoring software, current clamp, and communication cable. The instrument can store 3900 sets of data and enables online and real time monitoring, historical data inquiry, read, inquire storage, generation, and printing of a fitting curve. It is widely used in 380/220 power systems. It complies with IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ (600 V), and IEC61326 (EMC standard) safety codes.

  • Pathfinder Locating System

    The STICK™ - Rycom Instruments, Inc.

    Built with Pathfinder SAF Technology™ at its core, the Stick offers RYCOM’s most ophisticated technology in an economical package. Pathfinder SAF Technology™ is the heart of our premium locators, now RYCOM is applying this proven technology throughout the entire product line. From crowded easements, to long runs of pipe, to the most demanding of locating environments, users can depend on The Stick. Dependability is not only driven by the internal technology, but The Stick is built to last with an aluminum housing and sealed against weather. The ruggedly designed and well balanced receiver includes an LCD screen providing relative and actual signal strength, as well as a speaker for variable audio pitch. A peaking signal response allows the user to minimize interference and maintain the locate on the target conductor. The Stick cable and pipe locator offers multiple active frequencies — from 50Hz to 82kHz — ensuring flexibility to match the needs of the most complicated locating environments. Transmitter functions include transmitter induction, coupler induction and direct connection. Whether the locate is measured in feet or miles, with automatic impedance matching from 5 ohm to 25,000 ohms and 3 watts of output power, The Stick will meet the challenge. Rycom Instruments®, Inc. locators are designed and manufactured to make utility locating as accurate as you need and as simple as you want.

  • Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module

    MODEL TMO-2 - Transducer Techniques, Inc

    The TMO-2 Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The units provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Full scale output is specified at plus or minus 10 VDC. The TMO-2 provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability for applications such as weighing scales. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.

  • PXI-6733, 16-Bit, 8-Channel, 1 MS/s PXI Analog Output Module

    778512-01 - NI

    16-Bit, 8-Channel, 1 MS/s PXI Analog Output Module—The PXI‑6733 is a high-speed analog output device designed to deliver simultaneous, multichannel updates for control and waveform output applications, such as stimulus-response tests (including acoustic distortion testing) and simulation (such as three-phase power simulation). In addition, the device provides eight 5 V TTL/CMOS digital I/O lines; two 24‑bit, 20 MHz counter/timers; and digital triggering and external clocking capabilities. The PXI‑6733 can replace several kinds of instruments, including stand-alone proportional integral derivative (PID) controllers, low-speed arbitrary waveform generators, and function generators. You can control each data point for each channel to define common waveforms, such as square, sine, or sawtooth, as well as complex waveforms.

  • PXI-6722, 13-Bit, 8-Channel, 800 kS/s PXI Analog Output Module

    778999-01 - NI

    13-Bit, 8-Channel, 800 kS/s PXI Analog Output Module—The PXI‑6722 is a high-speed analog output device designed to deliver simultaneous, multichannel updates for control and waveform output applications, such as stimulus-response, power supply control, high-speed, deterministic control, and sensor/signal simulation. In addition, the device provides eight 5 V TTL/CMOS digital I/O lines; two 24‑bit, 20 MHz counter/timers; and digital triggering and external clocking capabilities. The PXI‑6722 can replace several kinds of instruments, including stand-alone proportional integral derivative (PID) controllers, low-speed arbitrary waveform generators, and function generators. You can control each data point for each channel to define common waveforms, such as square, sine, or sawtooth, as well as complex waveforms.

  • PXI 5A Fault Insertion Switch 5-Channel

    40-196-101 - Pickering Interfaces Ltd.

    The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.

  • PXI 5A Fault Insertion Switch 10-Channel

    40-196-001 - Pickering Interfaces Ltd.

    The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.

  • PXI-6711, 12-Bit, 4-Channel, 1 MS/s PXI Analog Output Module

    777794-01 - NI

    12-Bit, 4-Channel, 1 MS/s PXI Analog Output Module—The PXI‑6711 is a high-speed analog output device designed to deliver simultaneous, multichannel updates for control and waveform output applications, such as stimulus-response, power supply control, high-speed, deterministic control, and sensor/signal simulation. In addition, the device provides eight 5 V TTL/CMOS digital I/O lines; two 24‑bit, 20 MHz counter/timers; and digital triggering and external clocking capabilities. The PXI‑6711 can replace several kinds of instruments, including stand-alone proportional integral derivative (PID) controllers, low-speed arbitrary waveform generators, and function generators. You can control each data point for each channel to define common waveforms, such as square, sine, or sawtooth, as well as complex waveforms.

  • PXI-6713, 12-Bit, 8-Channel, 1 MS/s PXI Analog Output Module

    777795-01 - NI

    12-Bit, 8-Channel, 1 MS/s PXI Analog Output Module—The PXI‑6713 is a high-speed analog output device designed to deliver simultaneous, multichannel updates for control and waveform output applications, such as stimulus-response, power supply control, high-speed, deterministic control, and sensor/signal simulation. In addition, the device provides eight 5 V TTL/CMOS digital I/O lines; two 24‑bit, 20 MHz counter/timers; and digital triggering and external clocking capabilities. The PXI‑6713 can replace several kinds of instruments, including stand-alone proportional integral derivative (PID) controllers, low-speed arbitrary waveform generators, and function generators. You can control each data point for each channel to define common waveforms, such as square, sine, or sawtooth, as well as complex waveforms.

  • Automated Tuners / Impedance Tuners / Load Pull Tuners

    Maury Microwave Corporation

    MT97x, MT98x and XT98x series automated tuners (also known as automated impedance tuners and automated load pull tuners) are precision instruments that are optimized for a broad class of in-fixture and on-wafer applications, and may be used in any automated or manual application requiring the ability to match the impedance of a microwave circuit element or to establish specific impedances at a terminal interface. The tuner design is based on the slide screw concept using the inherently broadband slab-line transmission structure. Each unit has two non-contacting probes deliver high VSWR with superb accuracy and reliability over a wide frequency range. These probes can be fully retracted leaving a low-loss, well-matched transmission line, which is a significant benefit in power related applications where two-port tuners capable of handling large amounts of power are required. As integral components of Maury Device Characterization Solutions, these PC-based tuners are controlled using Maury's family of Device Characterization Software tools, including MT930 IVCAD, MT993 ATS and the DLL-based measurement automation environment. Maury Microwave automed impedance tuners are ideal for load pull, harmonic load pull, active load pull, hybrid active load pull, noise figure, noise parameters and all automated tuner applications.

  • [5kV AC/6kV DC] Hipot and Insulation Resistance Tester, Rise/Fall-Time Control Function Equipped

    TOS5300 Series - Kikusui Electronics Corp.

    The "TOS5300 Series" is a series of test instruments used in Hipot (withstanding voltage) tests and insulation resistance tests, two of the four tests regarded as necessary for ensuring the safety of electrical products. With an output of 5 kV/100 mA (AC) and 6 kV/10 mA (DC), the series can be used in Hipot (withstanding voltage) & insulation resistance testing of electronic equipment and electronic parts, based on the requirements of IEC, EN, UL, VDE, JIS, and other international safety standards and the Electrical Appliance and Material Safety Law. Also, the test voltage stability is improved with the adoption of a newly developed switching amplifier. Since the output voltage can be kept constant even when the AC line voltage or frequency changes, consistent testing can be performed, even when the power supply environment is in an unstable region. The TOS5300 is also equipped with a number of features that are capable of meeting a variety of test needs. It is a new low-cost standard model that provides thorough operability, reliability and safety.

Get Help